Type mv 105 cable, 500 kcmil, 5kv8kv, simpull type mv 105 cable, 500 kcmil, 5kv 3% insulation, 8kv, 100% insulation, simpull register or log in with your rexel account for price or to order. Ampacity and other design considerations for medium. In fact, the ampacity tables for mv cable given in article 310 are based on grounding at one end only. Our medium voltage mv cables are manufactured to support constructions at this level, and our customers trust us with supplying the highest standards of electrical equipment. Three phase operation in duct per 2017 nec table 310. The accuracy of the calculation provides increased confidence in the design, upgrading, and analysis projects.
As a result, general cable offers a wide range of medium voltage industrial cables from 2. For other installation conditions refer to the nec. However, epr is more flexible and can be rated for higher ampacity when rated at 105 degrees c. Xxmm 115 mils nlepr 5kv 3%8kv 100% ins level 25%ts sr tcer 105. These cable solutions include nonshielded type mv90 and copper tape shielded type mv105 designs used extensively in pulp. Medium voltage conductor ampacities copper conductor size awgkcmil 2001 5000 v 5001 35000 v 90 c mv 90 105 mv 105 mv 90 mv 105 2 145 150 165 1 155 175 170 190 10 180 200 195 215 20 205 225 225 255 30 240 270 260 290. Levels, 115 mils, three conductor spec 6355 uniblend lf eprcopper tape shieldpvc, mediumvoltage power, shielded 15 kv, ul type mv105, 3% ins. Aeic cs8 specification for extruded dielectric shielded power cables rated for 5 through 46kv.
Mv 105, 3% jacketed epr 15kv class b stranded copper, extruded semiconductor shield, insulated with heat and moisture resistant epr 3% insulation level, with conductor jacket pvc, cpe, etc. Mv cable copper conductor size awg kcmil 2001 5000 v 5001 35000 v 90 c 105 c 90 c 105 c mv 90 mv 105 mv 90 mv 105 8 65 74 6 90 99 100 110 4 120 140 2 160 175 170 195 1 185 205 195 225 10 215 240 225 255 20 250 275 260 295 30 290 320 300 340 40 335 375 345 390 250 375 415 380 430 350 465 515 470 525 500 580. Medium voltage 15kv 3% copper conductor, copper tape. Phase identified and cabled with fillers and bare copper ground conductor. Southwire 95505499 southwire 95505499 type mv105 cable. Cables are also suitable for direct burial if installed in a system with a grounding conductor that is in close proximity and conforms with article 250. Finding their use in power circuits in open air, conduit, or duct a variety of constructions and types of medium voltage power cable are available based on industrial. Cables are suitable for use as per nec 2008 and nec 2011 article 328 as feeders and branch circuits. If shields are grounded at both ends, the cable must be derated because the circulating current in the shield reduces the thermal capacity of the cable. Ampacity of cu 15kv cable in covered cable tray triplex single conductor 12032017 1.
The core can be used with solid or stranded copper or aluminium in both singles and triplex, and. Mv 105 shielded 5kv three phase identified conductors, cabled with fillers and bare copper ground conductor. Mv105 power cables, energy system and telecom solutions. Dec 07, 2016 first, in my experience, most 105c rated cable is in the mv category that i have dealt with personally and rated for greater than 2000 volts. Southwire simpull r power cable ul xxx awg cu 115 mils nlepr 5kv 3%8kv 100% ins level 25%ts mv 105 for ct use st1 sun res nesc csa xxx awg cu x. One stop buy has the top 15 kv cables and unbeatable service and industry expertise. Mv105 medium voltage cable wire, cables, cords gexpro. The above dimensions are approximate and subject to normal manufacturing tolerances. First, in my experience, most 105c rated cable is in the mv category that i have dealt with personally and rated for greater than 2000 volts. These cable solutions include nonshielded type mv 90 and copper tape shielded type mv 105 designs used extensively in pulp.
Epr insulation pvc jacket mv 105 3% insulation level 15kv 3 conductor. Gridcablemax hv cable sizing software made for engineers. Medium oltage single conductor 5 kv 35 kv cme wire. Medium voltage power cable hwc is a leading national provider of medium voltage mv power cable products for the electrical distribution sector in ranges from 2. Mediumvoltage power cable electric utilit empowr fill lf. General cable s uniblend copper tape shielded mediumvoltage cable is available in copper and aluminum conductor constructions with a metallic shield of annealed copper tape, leadfree insulation, and a flame retardant pvc jacket. Corflex mv 105 or mchl cables in this catalog are designed for use on power circuits. Mv90 5kv xlpepvc single conductor shielded power cable. The use of this table for establishing ampacity ratings is an inexact procedure. Voltage drop calculation for mv cable electric power. Medium voltage cables to iec 60502caledonian medium voltage. Our software has been designed to calculate the current rating, temperature rise and cable losses of high voltage power cables under multiple scenarios and installation conditions in accordance with iec standard 60287.
Shop for mv 105 in medium voltage cable from gexpro where contractors and project managers can find the electrical mv 105 products they need for their projects. Ampacity and other design considerations for medium voltage cables used in renewable energy applications earle c. Mediumvoltage power cable electric utilit telephone4 tss di il is k 41076753 800. The single core cables are designed for distribution of electrical power with nominal voltage uou ranging from. Home products medium voltage primary underground distribution. Cable ampacity software cable sizing software cable derating. Medium voltage cable okonite single conductor mv medium voltage cables 5kv to eff. Sizes 10 and larger marked for ct use and pass ul 1685 70,000 btuhr flame test conductors. The app will calculate the conduit fill percentages and jam probability for multiple conductors per nec guidelines. Mv 105 3 conductors cabled with suitable fillers when required and bare copper ground conductor. Mv 105 3 conductors cabled with suitable fillers when required and bare copper ground. There does, however, remain some ambiguity over where the medium voltage cable band begins and ends, depending on the countries, the standard setting bodies, and the type of. Ampacity of cu 15kv cable in covered cable tray triplex.
Ampacity copper and aluminum type mv90 and mv105 cables author. Ampacity amps conductor diameter 105c in duct 105c in air. Medium voltage cables, or mv cables, is a category defined by the international electrotechnical commission iec as having a voltage rating of above 1kv up to 100kv. This type of cable is listed, for purposes of ampacity, in tables 310. Type mv 105 15kv 3% copper conductor, copper tape shielded part number power conductor size nominal insulation thickness diameter over insulation jacket thickness outer diameter cable weight ampacities awgmcm mils in. The calculation determines the proper cable sizes to carry specified loads in designing new systems and upgrading power cable installations.
Southwires power cable installation guide provides installation information for extruded dielectric power cable systems. This guide covers copper and aluminum conductors from 14 awg through kcmil, insulated for operation from 600v though 35kv. Spec 6275 uniblend eprcopper tape shield with overall cpe jacket mediumvoltage power, shielded, 5 kv and 8 kv, ul type mv105 3%100% ins. Corflex cables are ul listed as marine shipboard cable file e869 600vv.
Cable core covered with binder tape and overall pvc jacket. Mv 105 cables with copper or aluminum conductor sizes ranging from 2 awg to kcmil 35 to 500 mm 2. Another insulation material is treeretardant xlp containing special additives that. Get free shipping on this 5kv shielded cable, plus all cut cables. Type mv105 15kv 3% copper conductor, copper tape shielded. Listed as type mv 105 per ul 1072 and meets the requirements of icea s93639. The software examines cable temperature and ampacity in performing analysis of existing systems. Aluminum conductor 15kv 3% mv105 eprpvc copper tape shield. Suggested ampacities all types of single conductor insulation. Voltage drop calculation for mv cable dpc electrical 30 aug 05 14. Our mediumvoltage cable is manufactured with copper conductor constructions with a metallic shield of annealed copper tape, leadfree insulation, and a flame retardant pvc jacket.
Three single cables, installed in uncovered cable tray in accordance with nec section 392. Ampacity type mv 90 and mv 105 cables, copper and aluminum mv 90 2. Ul listed as type mv 105 for use in accordance with nec. Ul 1685 ft4st1 verticaltray fire propagation and smoke release test 10 and larger csa c22. All 4conductor values have been derated per 2008nec table310. Cable ampacity software cable sizing software cable. The cold shrink splice body is a onepiece molded design made.
Ampacity and other design considerations for medium voltage. Simply enter the conduit type and size, then specify your conductors. This table should only be used as a starting point when establihsing ratings for any given situations. Based on not more than three conductors in raceway or cable or earth per nec table 310. Gencable 5000v and 8000v type mv 105 shielded single conductor 5kv medium voltage power cable is designed for industrial and commercial applications including chemical and petrochemical plants. These cables deliver superior performance in a wide range of. The insulation in our mv cables varies from paper to epr, pvc and xlpe. Eprcpe power cable with copper wire shield 25kv and 35kv ul type mv 105, 3% ins. Name ascending name descending 15kv epr concentric neutral pe jacket. Southwires trxlpe insulated 15kv hvtc is a csa copper tape shielded cable for industrial and commercial medium voltage applications. Cable ampacity power system software and arc flash hazard. This guide provides recommendations on procedures and. Cme wire and cable 495 horizon drive ne, suite 100, suwanee, georgia 30024. Gridcablemax is a user friendly program that determines cable ratings with total accuracy.
Utilities also use these products in substations and generating plants. It is recommended that design engineers desiring accurate ampacity data study the national electrical code handbook article 31031084. They are suitable for installation mostly in power supply stations. For ambient temperatures other than 40c 104f, multiply the ampacities shown above by the appropriate factor shown below. Epr insulation pvc jacket mv 105 power copper tape shield copper single conductor ungrounded. Medium voltage cables mv 105 and mv ud voltage ratings voltage rating insulation level nominal thickness mils.
Cable core covered with binder tape, aluminum or galvanized interlocked armor and yellow pvc jacket. Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system. For allowable ampacities for fixture wire, please see the national electrical code handbook. Southwire simpull ct109et type mv 105 cable is for use in aerial, direct burial, cable trays, conduit, and underground duct installations as permitted by the national electrical code.
1323 492 407 413 85 464 812 105 1613 641 678 1185 51 1350 1134 1528 389 1354 991 1617 727 805 1080 718 706 291 295 709 401 755 1113 213 314 78 850 1160 1543 719 221 281 20 174 1118 608 67 1267 539